UPD_DBCON_ENTRY_SDB not available as Remote-Enabled module
Hi guys, This is my first question in here, so excuse me if i seem to be in outside of usual formats Okay, my scenario is this:: I have to call the function UPD_DBCON_ENTRY_SDB from a VBA...
View ArticleRe: UPD_DBCON_ENTRY_SDB not available as Remote-Enabled module
Hi, currently I can give the following inforamtion:SAP Basis Version 46C -> function is NOT remote useableSAP Basis Version 740 -> function is remote useable Which SAP releases do you need to...
View ArticleSAP system copy problem with the log file
Hallo, currently I make an SAP system copy with the following components. The source system (windows2003):- SAP instance DEC- MaxDB Version 7.8.02.23- MaxDB Studio 7.9.08.00- The logfile are in the D:...
View ArticleRe: SAP system copy problem with the log file
Hi Richard, actions on source system are correctly done.But on the target system you may not delete the log volume ( in your case a file) even when a data backup only contains the application data and...
View ArticleRe: Emergency shutdown problem
Ok, you might want to report this via SAP OSS ticket as well (to have the crash checked), but otherwise my recommendation above remains valid (disable UseSharedSQL if this occurs more frequently...)....
View ArticleRe: UPD_DBCON_ENTRY_SDB not available as Remote-Enabled module
Hi Christiane, Thanks for the information. Also, can you please tell me from which version onwards the remote enable flag was set? That being known, i can set a compatibility range for my application...
View ArticleRe: UPD_DBCON_ENTRY_SDB not available as Remote-Enabled module
Hello Geroge, I check starting with Basic version 46C - but the function UPD_DBCON_ENTRY_SDB can be executed externally as of SAP Version 730 only. The function module INS_DBCON_ENTRY_SDB is...
View ArticleRe: SAP system copy problem with the log file
Hello Christiane, thank you for your answer..... MARK check box initialize Database before Recovery -> NEXT Then choose the backup and change the configuration of the source system which is...
View ArticleRe: UPD_DBCON_ENTRY_SDB not available as Remote-Enabled module
Thanks again Christiane, I will look more into the INS_DBCON_ENTRY_SDB function. But when i checked the source code for this module, it is used for inserting a new connection entry, and not for...
View ArticleRe: SAP system copy problem with the log file
Hi Richard, sounds like an error in DBStudio- but would you pelase try to run the Restore as I told you with the Initialize flag. This is the recommended way to do a system copy. Do you get the same...
View ArticleRe: Emergency shutdown problem
Hi Thorsten, thanks for your post. It would be great if you could provide me a Sapmats container that I can use to upload the Heapdump. On the other hand we switched off the UseSharedSQL and we'll see,...
View ArticleRe: UPD_DBCON_ENTRY_SDB not available as Remote-Enabled module
Hello George, there does not exist any function to drop DBCON entries remotely - I think.The function INS_DBCON_ENTRY_SDB is used by the SAP installation tools and therefore is a remote function...
View ArticleRe: SAP system copy problem with the log file
Hi Christiane, yes, with the "initialize database" first and I get the same error message... Regards,Richard
View ArticleRe: UPD_DBCON_ENTRY_SDB not available as Remote-Enabled module
Hi Christian, i do not have to call any ABAP function module to drop the DBCON entry. I can directly use drop sql statement on the database to drop the corresponding row in DBCON table.But now that you...
View ArticleRe: Emergency shutdown problem
Hi Sven, here is the Sapmats link: https://sapmats-de.sap-ag.de/upload/index.cgi?id=50YEKZPZKHK0TENJL0AUZS1N3KDA1PYOPKH1BJ9M38OCYUCQE9 Please note that this Sapmats link is only valid for today and...
View ArticleRe: SAP system copy problem with the log file
Hi Richard, it look like the problem is caused by mirrored log - could you do the system copy with logmirrored NO? Regards, Christiane
View ArticleRe: SAP system copy problem with the log file
Hi Richard, ok - it sounds more and more strange.I could not reproduce this issue so far in my envirnoment. Are you a SAP customer? Then please open an official SAP ticket on component...
View ArticleRe: SAP system copy problem with the log file
Hi Christiane,thank you for your help!Yes it is realy strange. I found a older Max Studio in my archive (7.9.08.07) but the same reaction.I tryed again with the following approach:1) delete the log...
View ArticleRe: Emergency shutdown problem
Thanks Thorsten for your help. I just uploaded the Heapdump-file.
View Article